Challenges
- Through-wall defect caused by external corrosion
Benefits
- 10-year engineered composite repair
- No hot work
Scope
ICR was engaged by a major UK power company to repair a spare carbon steel conservator tank containing insulation oil to BS 148. The tank had suffered a through-wall defect caused by external corrosion.
Technowrap™ engineered composite repair was the optimal solution chosen for this scope. Providing a cold-work alternative to costly conventional welding or replacement, this avoided the need for hot work on the tank, helping reduce associated safety risks and simplifying the repair process within a power generation environment.
The repair was engineered for a 10-year design life, and to be compatable with the tank’s operating temperatures from -15°C to 40°C and T/patch geometry.
Solution
ICR provided the surface preparation equipment and personnel, preparing the repair area to ST3 cleanliness with a minimum surface roughness of 40 microns.
The Technowrap™ repair was completed using nine layers of 2K cloth with low-temperature resin, restoring the integrity of the affected area and resulting in a total repair extent of 480 mm.

Result
- Through-wall defect successfully addressed
- Engineered composite repair delivered with 10-year design life
- Cold-work solution avoided hot work and delivered in minimal time
Explore ICR’s Service for Power Sector
ICR’s cold-work repair and maintenance solutions offer significant benefits to nuclear and power sites – find out more by clicking here.
Featured articles
Technowrap™ Awarded Bureau Veritas (BV) Type Approval
ICR Completes Major Composite Repair Project in the Marine Sector